The Carlo Gavazzi EM24 Energy Analyser delivers comprehensive three-phase electrical power monitoring, certified metering accuracy, and flexible communication telemetry engineered specifically for industrial motor control centers, building automation networks, commercial sub-metering panels, and renewable solar energy systems.

Advanced Power and Energy Management with the Carlo Gavazzi EM24 Energy Analyser

Designed to consolidate power analysis within high-density switchboards, the Carlo Gavazzi EM24 Energy Analyser captures real-time electrical performance across single-phase, two-phase, and three-phase power distribution circuits. The instrument records true RMS variables—including phase-to-neutral voltages, phase-to-phase voltages, line currents, active power (kW), reactive power (kvar), apparent power (kVA), grid frequency, and individual phase power factors—enabling accurate electrical tracking across variable and non-linear process loads.

The analyser is engineered for simple on-site deployment, featuring a distinctive front micro-joystick that allows commissioning technicians to configure current transformer (CT) and potential transformer (PT) ratios, address settings, and measurement pages rapidly. Available in direct-connection versions up to 65 A as well as standard 5 A CT-operated configurations, the meter supports bidirectional energy counting to track both imported and exported active kilowatt-hours for distributed solar generation and net-metering facilities.

For facility-wide supervisory integration and energy management accounting, the device incorporates an optically isolated RS485 serial communication interface supporting standard Modbus RTU protocol. In addition to digital fieldbus telemetry, the EM24 provides digital pulse outputs and auxiliary digital inputs, supporting dual-tariff energy tracking, remote breaker status monitoring, and direct coupling to facility SCADA systems.

Key Features and Engineering Advantages

  • True RMS Three-Phase Analysis: Delivers precise calculation of electrical variables under distorted harmonic waveforms and fluctuating power conditions.
  • Direct and CT-Rated Flexibility: Accommodates direct-feed branch circuits up to 65 A or standard 5 A secondary current transformers with programmable primary scaling.
  • Ergonomic Joystick Configuration: Simplifies setup and display scrolling via an integrated front selector switch, eliminating complex button combinations.
  • Bidirectional Four-Quadrant Metering: Tracks active and reactive energy in both import and export directions for complete solar and battery storage accounting.
  • Space-Saving 4-DIN Chassis: Slim 72 mm footprint snaps directly onto 35 mm DIN rails (EN 60715) or mounts on panel doors with an optional adapter frame.

Technical Specifications

Technical Parameter Specification Details
Product Series Carlo Gavazzi EM24 Series Energy Analyser
System Architectures 3-phase 4-wire (3P4W), 3-phase 3-wire (3P3W), 2-phase 3-wire, 1-phase 2-wire
Voltage Input Range 115 to 400 V AC Line-to-Neutral / 208 to 690 V AC Line-to-Line (45 to 65 Hz)
Current Input Options Direct feed: 10(65) A; CT feed: 5(10) A (programmable CT ratio up to 60,000 A)
Metrological Accuracy Class 1 (IEC 62053-21) / Class B (EN 50470-3); Class 2 Reactive (IEC 62053-23)
Digital Telemetry RS485 serial port (Modbus RTU protocol, baud rate up to 115,200 bps)
Digital I/O Channels Up to 2 static optocoupler pulse outputs (or 2 digital inputs for dual tariff management)
Display Architecture Backlit LCD (3 × 4-digit display plus active indicators and totalizers)
Auxiliary / Self Power Self-powered from voltage inputs or separate auxiliary power supply (model dependent)
Enclosure Standard Self-extinguishing Noryl, 4-DIN modules wide (72 × 89 × 65 mm)
Ingress Protection IP50 (front panel); IP20 (screw connection terminals)
Operating Ambient Limits -25 °C to +55 °C (-13 °F to +131 °F); ≤ 90% non-condensing RH

Industrial Applications and Process Integration

The Carlo Gavazzi EM24 Energy Analyser is installed across commercial, utility, and automated facility infrastructure, including:

  • Main switchboards, sub-distribution panels, and motor control centers (MCC) in manufacturing plants.
  • Commercial tenant energy allocation and multi-zone sub-metering across office complexes and retail centers.
  • Solar photovoltaic inverter export monitoring, microgrid management, and energy storage systems.
  • Facility energy management platforms aligned with ISO 50001 corporate power efficiency mandates.

Frequently Asked Questions

What is the purpose of the joystick on the Carlo Gavazzi EM24 Energy Analyser?
The integrated front micro-joystick allows technicians to navigate menus, select displayed electrical parameters, and configure system settings directly on the device without having to connect external programming tools or software interfaces.

Can the meter differentiate between power consumed and power fed back into the grid?
Yes. The Carlo Gavazzi EM24 Energy Analyser features bidirectional energy registers that record forward (imported) and reverse (exported) active energy independently, making it suitable for renewable solar PV arrays and grid feed-in monitoring.

How are the digital inputs used in energy management applications?
On models equipped with digital inputs, the terminals can be wired to utility signals to switch between tariff rates (e.g., peak vs. off-peak energy billing) or configured to count external pulses from water and gas sub-meters.

Reviews (0)

Be the first to review “Carlo Gavazzi EM24 Three-Phase Energy Analyser”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!